logo

The Sarstedt S-Monovette® is an innovative, enclosed multiple-sampling blood collection system. S-Monovette® tubes can be gently filled by manual aspiration to minimize shear stress associated with vacuum tubes and I.V. catheters. Compared to untreated syringes, S-Monovette® tubes contain a range of additives and can be processed directly with no transfer, maintaining a closed connection.







Supporting Evidence-Based Research

S-Monovette® system reduces overall hemolysis 15-fold and practically eliminates subsequent rejection compared to vacuum tube collection

Goegubuer, Debrabandere. Clinical Laboratory, H-Hartziekenhuis Roeselare-Menen vzw. Influence of the serum collection system on hemolysis. Focus Diagnostica 2008;16(2):22-25.

Lippi G, Avanzini P, Cervellin G. Prevention of hemolysis in blood samples collected from intravenous catheters. Clin Biochem 2013;46(7-8):561-4.

Total cost of specimen recollection per facility ranges from $200,000 - $300,000 annually

Ong MSE, Chan YH, Lim CS. Reducing blood sample hemolysis at a tertiary hospital emergency department. Am J Med 2009;122(11):1054.e1-6.

Latino B and Belliveau R. LEAPTM analysis system analyzed; blood drawing process. Opportunity analysis. Specimen Integrity OA Reliability Center, Inc. (2011).

Carlson R, Amirahmadi F, Hernandez J. A primer on the cost of quality for improvement of laboratory and pathology specimen processes. Am J Clin Pathol 2012;138:347-354.

Specimen rejection leads to poor patient care and decreased patient satisfaction, and contributes to ED overcrowding and LOS

2011 CAP Q-Probes study QP114 “Clinical Consequences of Specimen Rejection”

2006 Emergency Nurses Association White Paper “Holding Patients in the Emergency Department”

Pennsylvania Patient Safety Authority. In Vitro hemolysis: delays may pose safety issues. PA-PSRS Patient Safety Advisory 2007;4(2):64-66.

Astion M, Shojania K, et al. Classifying laboratory incident reports to identify problems that jeopardize patient safety. Am J Clin Pathol 2003;120:18-26.

Carraro P and Plebani M. Errors in a Stat laboratory: types and frequencies 10 years later. Clin Chem 2007;53(7):1338-42.

Direct tube sampling saves over 100 minutes of technologist aliquoting time every day

Weinzierl EP, Brawley C, Adams JL, Rogers BB. Validation of an Enclosed Blood Collection System in a Pediatric Laboratory. JALM 2018; 03:01: 65-78.

Blood collection with the S-Monovette® system was recognized by The Joint Commission as a “Best Practice” in 2018

Pilla RV, Lemieux JA, Huss JL. Reducing Hemolysis with the Sarstedt S-Monovette® Blood Collection System. Emergency Services, Wright-Patterson AFB poster 2018.













default_image



Generating Request  

Form submitted. Your samples are on the way!


Please fill out the following information and click Submit Request to receive a sample.